Class A

 

1. Deck: C-15/32

Incline: Unlimited

Impact: Class 4

Barrier Board: — Minimum 1/4 in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roof Board", with all joints staggered a min of 6 in. from the plywood joints
Ply Sheet (Optional): — Any UL Classified Type G1, Type G2 or Type G3 base/ply sheet, Type 15, Type 20 or Type 30 felt, or UL Classified Prepared Roofing Accessory (TGDY).
Surfacing: — Coated steel, aluminum, copper, or zinc roofing panels designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.

2. Deck: C-15/32

Incline: Unlimited

Impact: Class 4

Slip Sheet (Fire Barrier): — One or more layers of GAF "VersaShield® Solo™ Fire Resistant Slip Sheet", mechanically fastened.
Surfacing: — Coated steel, aluminum, or copper roofing panels designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.

3. Deck: C-15/32

Incline: Unlimited

Impact: Class 4

Underlayment: — One or more plies GAF "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened.
Surfacing: — Coated steel or copper roofing panels designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.

4. Deck: C-15/32

Incline: Unlimited

Impact: Class 4

Underlayment: — Two or more plies GAF "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened.
Surfacing: — Coated aluminum roofing panels designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.

5. Deck: C-15/32

Incline: Unlimited

Impact: Class 4

Underlayment: — One ply Holcim Solutions and Products "CLAD-GARD SA-FR" self-adhered underlayment.
Surfacing: — Coated steel, aluminum, or copper roofing panels designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.

6. Deck: C-15/32

Incline: Unlimited

Impact: Class 4

Slip Sheet: — Two layers Atlas Roofing Corp "FR50".
Base Sheet (Optional): — Type 15 or 30 or any UL Classified self-adhering underlayment.
Surfacing: — Coated steel roofing panels (minimum 28 gauge) designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.

7. Deck: C-15/32

Incline: Unlimited

Impact: Class 4

Underlayment: — One ply Polyglass USA "Polystick XFR" self-adhered.
Insulation (Optional): — Any UL Classified polyisocyanurate, perlite, wood fiber or polyisocyanurate/perlite board, any thickness mechanically fastened or adhered with any UL Classified insulation adhesive.
Surfacing: — Coated steel roofing panels (minimum 26 gauge) designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.

8. Deck: C-15/32 or spaced sheathing

Incline: Unlimited

Impact: Class 4

Base Sheet (Optional): — Minimum one ply Type 15 or Type 30 asphalt saturated felt or Type G1 or Type G2 asphalt saturated glass mat, mechanically fastened.
Underlayment: — One ply Polyglass USA "Polystick XFR" self-adhered.
Insulation (Optional): — Any UL Classified polyisocyanurate, perlite, wood fiber or polyisocyanurate/perlite board, any thickness mechanically fastened or adhered with any UL Classified insulation adhesive.
Surfacing: — Coated steel roofing panels (minimum 26 gauge) designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.

9. Deck: C-15/32 or spaced sheathing

Incline: Unlimited

Impact: Class 4

Joint Treatment (Optional): — "Polystrip SA", self-adhered over plywood joints.
Base Sheet (Optional): — Minimum one ply Type 15 or Type 30 asphalt saturated felt or Type G1 or Type G2 asphalt saturated glass mat, mechanically fastened.
Underlayment: — Two plies "Polystick XFR" self-adhered.
Insulation (Optional): — Any UL Classified polyisocyanurate, perlite, wood fiber or polyisocyanurate/perlite board, any thickness mechanically fastened or adhered with any UL Classified insulation adhesive.
Surfacing: — Coated aluminum roofing panels designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.

10. Deck: C-15/32

Incline: Unlimited

 

Base Sheet (Optional): — One or more plies of any UL Classified self-adhered underlayment.
Underlayment: — Two or more plies GAF "VersaShield® Fire-Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened.
Surfacing: — Coated zinc roofing panels designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.

 

Class C

 

1. Deck: C-15/32

Incline: Unlimited

Impact: Class 4

Base Sheet (Optional): — Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified Prepared Roofing Accessory (TGDY).
Surfacing: — Coated steel, aluminum, copper, or zinc roofing panels designated “SM SS450”, “SM SS150”, or “SM SS200”, mechanically fastened.